Datasheet File OCR Text: |
MICROCHANNEL PLATEPHOTOMULTIPLIER TUBE R3809U-61/-63/-64 Compact High Sensitivity MCP-PMT Series Featuring with Fast Time Response FEATURES GHigh Sensitivity QE: 12 % (-61), 36 % (-63), 40 % (-64) GHigh Speed Rise Time: 200 ps (-61), 180 ps (-63/-64) IRF A (Instrument Response Function): 150 ps at FWHM: (-61) 60 ps at FWHM: (-63/-64) GCompact Profile Effective Photocathode: 10 mm diameter (Overall length: 70.2 mm, Outer diameter: 45.0 mm) APPLICATIONS GMolecular Science Analysis of Molecular Structure GMedical Science Optical Computer Tomography GBiochemistry Fast Gene Sequencing GMaterial Engineering Semiconductor Analysis Crystal Research GLidar Figure 1: Spectral Response TPMHB0756EA Figure 2: Typical Gain 107 TPMHB0179EA 1000 R3809U-64 R3809U-61 100 106 RADIANT SENSITIVITY (mA/W) QUANTUM EFFICIENCY (%) CURRENT GAIN 10 105 1 R3809U-63 104 0.1 103 0.01 200 300 400 500 600 700 800 900 1000 102 -2.0 -2.2 -2.4 -2.6 -2.8 -3.0 -3.2 -3.4 WAVELENGTH (nm) SUPPLY VOLTAGE (kV) Subject to local technical requirements and regulations, availability of products included in this promotional material may vary. Please consult with our sales office. Information furnished by HAMAMATSU is believed to be reliable. However, no responsibility is assumed for possible inaccuracies or omissions. Specifications are subject to change without notice. No patent rights are granted to any of the circuits described herein. (c)2007 Hamamatsu Photonics K.K. MCP-PMT R3809U-61/-63/-64 SPECIFICATIONS GR3809U-61/-63/-64 GENERAL Parameter Spectral Response Peak Wavelength Photocathode Material Window Material Effective Area of PMT Stage of MCP B Operating Ambient Temperature Storage Temperature R3809U-61 370 to 920 600 to 750 GaAs R3809U-63 280 to 820 480 to 530 Extended Red GaAsP Borosilicate Glass 10 2 -50 to +50 -50 to +50 R3809U-64 280 to 720 480 to 530 GaAsP Unit nm nm -- -- mm -- C C MAXIMUM RATING Parameter PMT Supply Voltage Average PMT Anode Current Pulsed Peak Current C R3809U-61 R3809U-63 -3400 100 350 R3809U-64 Unit V nA mA CHARACTERISTICS (at -3000 V, +25 C) Parameter Luminous D Cathode Sensitivity Quantum Efficiency Gain Anode Dark Count E Rise Time F Time Fall Time G Response IRF (FWHM) A Min. 400 -- 1 x 105 -- -- -- -- R3809U-61 Max. Typ. -- 700 -- 12 -- 2 x 105 -- 20 H -- 200 -- 500 -- 150 Min. 450 27 1 x 105 -- -- -- -- R3809U-63 Typ. Max. 750 -- 36 -- 2 x 105 -- -- 3 x 103 -- 180 -- 400 -- 60 Min. 400 30 1 x 105 -- -- -- -- R3809U-64 Typ. Max. 700 -- 40 -- 2 x 105 -- -- 3 x 103 -- 180 -- 400 -- 60 Unit A/lm % -- s-1 ps ps ps NOTE: A IRF stands for Instrument Response Function which is a convolution of the pulse function (H(t)) of the measuring system and the excitation function (E(t)) of a laser. The IRF is given by the following formula: IRF = H(t) x E(t) We specify the IRF as an FWHM of the time distribution taken by using the measuring system in Figure 5 that is Hamamatsu standard IRF measurement. It can be temporary estimated by the following equation: (IRF (FWHM))2 = (TTS)2 + (Tw)2 + (Tj)2 where Tw is the pulse width of the laser used and Tj is the time jitter of all equipments used. An IRF data is provided with the tube purchased as a standard. Transit-time spread (TTS) is the fluctuation in transit time between individual pulse and specified as an FWHM (full width at half maximum) with the incident light having a single photoelectron state. B Two microchannel plates (MCP) are incorporated as a standard but we can provide it with either one or three MCPs as an option depending upon your request. C This is specified under the operating conditions that the repetition rate of light input is 100 Hz or below and its pulse width is 70 picoseconds. D The light source used to measure the luminous sensitivity is a tungsten filament lamp operated at a distribution temperature of 2856 K. The incident light intensity is 10-4 lm and 100 V is applied between the photocathode and all other electrodes connected as an anode. E At 30 minutes after high voltage is applied with shutter closed F This is the mean time difference between the 10 % and 90 % amplitude points on the output waveform for full cathode illumination. G This is the mean time difference between the 90 % and 10 % amplitude points on the tailing edge of the output waveform for full cathode illumination. H At -30 C Figure 3: Typical Output Waveform GR3809U-61 TPMHB0757EA Figure 5: Typical Instrument Response Function (IRF) A GR3809U-61 TPMHB0759EA FWHM: 150 ps 104 RELATIVE COUNTS SUPPLY VOLTAGE : -3000 V RISE TIME : 200 ps FALL TIME : 500 ps WIDTH : 400 ps 103 10 (mV/div) 102 101 100 0.2 (ns/div) 0.5 (ns/div) GR3809U-63/-64 TPMHB0758EA GR3809U-63/-64 TPMHB0760EA FWHM: 60 ps 104 RELATIVE COUNTS SUPPLY VOLTAGE : -3000 V RISE TIME : 180 ps FALL TIME : 400 ps WIDTH : 300 ps 103 50 (mV/div) 102 101 100 0.2 (ns/div) 0.2 (ns/div) Figure 4: Block Diagram of Output Waveform Measuring System ND FILTER TRIGGER OUT PICOSECOND LIGHT PULSER HAMAMATSU MODEL#PLP-01 WAVELENGTH: 410 nm PULSE WIDTH (FWHM) : 35 ps TRIGGER IN R3809U-61/-63/-64 HAMAMATSU C4840 HIGH VOLTAGE POWER SUPPLY TEKTRONIX 11802 DIGITAL 50 LOAD SAMPLING OSCILLOSCOPE Figure 6: Block Diagram of IRF Measuring System HAMAMATSU PICOSECOND MODEL#PLP-01 WAVELENGTH: 410 nm LIGHT PULSER PULSE WIDTH (FWHM) : 35 ps TRIGGER OUT ND FILTER R3809U-61/-63/-64 HAMAMATSU C4840 HIGH VOLTAGE POWER SUPPLY HAMAMATSU C5594 ORTEC 457 AMP DELAY ORTEC 425A START TAC STOP CFD TENNELEC TC-454 COMPUTER MCA NAIG COMPUTER TPMHC0232EB TPMHC0233EB MCP-PMT R3809U-61/-63/-64 Figure 7: Dimensional Outlines (Unit: mm) GR3809U-61/-63/-64 EFFECTIVE PHOTOCATHODE DIAMETER 10 MIN. ALUMINUM HOUSING CASE PHOTOCATHODE SHV-R CONNECTOR (-HV INPUT) 45 3 4.20.1 52.5 70.20.3 7 17.7 SMA-R CONNECTOR (OUTPUT) TPMHA0522EA ACCESSORIES THERMOELECTRIC COOLING UNIT C10373 HIGH SPEED AMPLIFIER C5594 Series BENCH-TOP HIGH VOLTAGE POWER SUPPLY C4840 Series Specifications Cooling .................. Thermoelectric Effects Heat exchange Medium (coolant) ................. Water (1/3 litters/min. flow rate) Temperature controllable range ........................................... -30 C to 0 C Optical window material ......... Evacuated double-pane fused silica Note: C10373 reguires a holder (e.g E3059-500). Specifications Frequency Response Range ......... 50 kHz to 1.5 GHz Gain ....................................... 36 dB (Typ.) Input/Output Impedance .................... 50 Noise Figure (NF) .................... 7 dB (Typ.) Supply Voltage ................... +12 V to +16 V Recommend Input Voltage ............... +15 V Supply Current ...................... 95 mA (Typ.) Absolute Maximum Ratings Supply Voltage ................................. +17 V Input Power .................................... 10 mW Specifications Output Voltage .................. 0 V to 3000 V Maximum Output Current ...............10 mA Line Regulation Against 10 % Line Voltage Change AB (Max.) ....... (0.005 % + 10 mV) Load Regulation Against 0 % to 100 % Load Change A (Max.) ........... (0.01 % + 50 mV) Ripple / Noise (p-p) AB (Max.) ..... 0.0007 % Drift (after 1 h Warm-up) AB (Max.) ............................. (0.02 % + 10 mV)/8 h Temperature Coefficient AB (Max.) .. 0.01 % / C AC Input Voltage C4840-01 .... 120 V (10 %) (50 / 60 Hz) C4840-02 .... 230 V (10 %) (50 / 60 Hz) Power Consumption AB .... Approx. 100 V*A NOTE: AAt maximum output voltage BAt maximum output current WEB SITE www.hamamatsu.com HAMAMATSU PHOTONICS K.K., Electron Tube Division 314-5, Shimokanzo, Iwata City, Shizuoka Pref., 438-0193, Japan, Telephone: (81)539/62-5248, Fax: (81)539/62-2205 U.S.A.: Hamamatsu Corporation: 360 Foothill Road, P. O. Box 6910, Bridgewater. N.J. 08807-0910, U.S.A., Telephone: (1)908-231-0960, Fax: (1)908-231-1218 E-mail: usa@hamamatsu.com Germany: Hamamatsu Photonics Deutschland GmbH: Arzbergerstr. 10, D-82211 Herrsching am Ammersee, Germany, Telephone: (49)8152-375-0, Fax: (49)8152-2658 E-mail: info@hamamatsu.de France: Hamamatsu Photonics France S.A.R.L.: 19, Rue du Saule Trapu, Parc du Moulin de Massy, 91882 Massy Cedex, France, Telephone: (33)1 69 53 71 00, Fax: (33)1 69 53 71 10 E-mail: infos@hamamatsu.fr United Kingdom: Hamamatsu Photonics UK Limited: 2 Howard Court, 10 Tewin Road Welwyn Garden City Hertfordshire AL7 1BW, United Kingdom, Telephone: 44-(0)1707-294888, Fax: 44(0)1707-325777 E-mail: info@hamamatsu.co.uk North Europe: Hamamatsu Photonics Norden AB: Smidesvagen 12, SE-171-41 SOLNA, Sweden, Telephone: (46)8-509-031-00, Fax: (46)8-509-031-01 E-mail: info@hamamatsu.se TPMH1295E03 Italy: Hamamatsu Photonics Italia: S.R.L.: Strada della Moia, 1/E, 20020 Arese, (Milano), Italy, Telephone: (39)02-935 81 733, Fax: (39)02-935 81 741 E-mail: info@hamamatsu.it SEPT. 2007 IP |
Price & Availability of R3809U-61 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |